Operate the Plasma System
3
56 811470 Operator Manual Powermax45 SYNC
Indicator LEDs
Adjustment knob – Use this knob to set the cutting current between 9 A and 45 A in
1-unit increments.
You can also use this knob to increase or decrease the gas pressure. Refer to
Adjust the gas pressure manually on page 59.
Power ON LED (green)
When illuminated, this LED indicates that the power switch is set to ON (I) and the system is ready to
cut.
Gas Pressure LED (yellow)
When illuminated, this fault LED indicates that the inlet gas pressure is too low or that there is no inlet
gas connection. Refer to Fault icons and fault codes on page 96.
System Fault LED (yellow)
When illuminated, this fault LED indicates that there is a fault with the plasma power supply. In many
instances, when this LED illuminates, a fault code also flashes on the 2-digit display. Refer to Fault icons
and fault codes on page 96.
Torch Cap LED (yellow)
When illuminated, this fault LED indicates that the consumables are loose, improperly installed, or
missing. Refer to Fault icons and fault codes on page 96.
Temperature LED (yellow)
When illuminated, this fault LED indicates that the system’s temperature is outside the permitted
operating range. Refer to Fault icons and fault codes on page 96.
Service LED
This LED is used by qualified service technicians for troubleshooting the plasma power supply.