EasyManua.ls Logo

Hypertherm Powermax45 SYNC - Change a Cartridge; LED Behavior During a Cartridge Change

Hypertherm Powermax45 SYNC
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operate the Plasma System
3
Powermax45 SYNC Operator Manual 811470 53
Change a cartridge
1. Move the torch-lock switch to the yellow
lock (X) position.
2. Remove the cartridge and install a new one.
Refer to Install the cartridge on page 50.
3. Move the torch-lock switch to the green “ready
to fire” ( ) position.
4. Pull the torch trigger 1 time to get the warning
puffs of air.
LED behavior during a cartridge change
On the plasma power supply:
1 2 3
Yellow Yellow
Green
When you set the torch-lock switch to the yellow lock (X) position while the plasma power supply is
ON, the Torch Cap light-emitting diode (LED) on the front panel illuminates and a 0-50-2 code
displays.
After you install the cartridge and set the torch-lock switch to the green “ready to fire” ( )
position, the Torch Cap LED extinguishes.
Hand torch: After the torch puts out the warning puffs of air, the 0-50-2 code extinguishes.
1
2
3

Table of Contents

Related product manuals