Operate the Plasma System
3
52 811470 Operator Manual Powermax45 SYNC
Step 6 – Unlock the SmartSYNC torch
1. Move the torch-lock switch to the green “ready
to fire” ( ) position.
2. Pull the torch trigger 1 time to get the warning
puffs of air. Refer to Warning puffs of air on
page 52.
3. When the warning puffs of air stop, the torch is
prepared to fire a plasma arc.
If you see a fault code and fault icon on the control
panel, remove the fault condition before you
continue. Refer to Fault icons and fault codes on
page 96.
Warning puffs of air
The following happens on SmartSYNC hand torches the first time that you try to fire the torch after
moving the torch-lock switch to the yellow lock (X) position and then back to the green “ready to
fire” ( ) position:
This feedback is a warning. It does not identify a fault condition. It tells you that the torch is
unlocked and will fire a plasma arc the next time that you pull the trigger.
The plasma arc does not fire.
The torch quickly puts out multiple puffs of air. You can feel a light tap in the torch handle with each
puff of air.
The plasma power supply makes a pressure-release sound that you can hear with each puff of air.
1
2
3
1