EasyManua.ls Logo

Hypertherm Powermax45 SYNC - Go Back to Automatic Settings Mode

Hypertherm Powermax45 SYNC
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operate the Plasma System
3
60 811470 Operator Manual Powermax45 SYNC
Go back to automatic settings mode
To go back to automatic settings mode, push the Mode button . The selected mode LED next
to the button stops flashing.
When you change from manual gas pressure mode to automatic gas pressure mode:
The plasma power supply automatically sets the gas pressure related to the Hypertherm
cartridge.
The amperage setting stays the same.
When you change from automatic gas pressure mode to manual gas pressure mode:
The plasma power supply uses the last manual gas pressure that you set.
The amperage setting stays the same.
When you do a quick restart or a cold restart of the plasma power supply in manual
gas pressure mode:
The plasma power supply keeps the last manual gas pressure and amperage that you
set, unless you install a different type of cartridge.
When you connect a different torch, the plasma power supply returns to automatic gas
pressure mode.
1
2
12

Table of Contents

Related product manuals