Complete Regular Maintenance Tasks
7
116 811470 Operator Manual Powermax45 SYNC
With each cartridge change or each week (whichever is more frequent)
Torch
Do a test of the torch-lock switch to make sure
that it correctly locks and unlocks the torch.
Lock the torch :
With the plasma power supply ON, move
the torch-lock switch to the yellow lock (X)
position.
Point the torch away from yourself and
others.
Pull the trigger to make sure that the torch
does not fire.
Unlock the torch :
Move the torch-lock switch to the green
“ready to fire” ( ) position.
Point the torch away from yourself and
others.
Pull the trigger 1 time. Make sure that the
torch does not fire. Make sure that multiple
puffs of air quickly come from the torch
instead. Refer to Warning puffs of air on
page 52.
Have a qualified service technician replace the
torch-lock switch if it is not working correctly.
Speak to your distributor or authorized repair
facility.