Install and Set Up the Plasma Power Supply
2
Powermax45 SYNC Operator Manual 811470 33
CCC 380 V (3-phase)
CE 400 V (3-phase)
CSA 480 V (3-phase)
Input voltage 380 V
Input current at rated output (45 A x 145 V = 6.5 kW) 13 A
Input current during arc stretch 15 A 20 A
Fuse (time-delay) 20 A
Voltage tolerance +20% to -15%
Input voltage 400 V
Input current at rated output (45 A x 145 V = 6.5 kW) 12 A
Input current during arc stretch 15 A 20 A
Fuse (time-delay) 20 A
Voltage tolerance +20% to -15%
Input voltage 480 V
Input current at rated output (45 A x 145 V = 6.5 kW) 10 A
Input current during arc stretch 12 A 17 A
Fuse (time-delay) 20 A
Voltage tolerance +20% to -15%