Table 1. Service Processor Checkpoints. (continued)
Checkpoint Description Action/ Possible Failing FRU
E080 Entering service processor recovery
flash update process.
1. Do the following flash recovery
procedure:
a. Insert a newly formatted DOS
diskette loaded with service
processor firmware into the
diskette drive. The file name
must be
spflash.img
.
Note: Insert the diskette after
checkpoint E080 is displayed on
the operator panel.
b. Shut down the system unit and
unplug the power cable.
c. Plug in the power cable,
power-on the system unit.
2. Retry item 1 with a newly formatted
DOS diskette.
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
E081 Flash update completed - system reboot
in progress
1. Unplug the power cable.
2. Plug in the power cable, power-on
the system unit.
3. Do the following flash recovery
procedure:
a. Insert a newly formatted DOS
diskette loaded with service
processor firmware into the
diskette drive. The file name
must be
spflash.img
.
Note: Insert the diskette after
checkpoint E080 is displayed on
the operator panel.
b. Shut down the system unit and
unplug the power cable.
c. Plug in the power cable,
power-on the system unit.
4. Retry the flash recovery procedure
with a newly formatted DOS
diskette.
5. Replace the system board.
Location: P1
(See note 3 on page 115.)
E0A0 Beginning bring-up phase See “Error Codes E0A0, E0B0, E0C0,
E0E0, E0E1 and 40A00000 Recovery
Procedure” on page 177.
E0B0 Starting processor BIST See “Error Codes E0A0, E0B0, E0C0,
E0E0, E0E1 and 40A00000 Recovery
Procedure” on page 177.
90 Service Guide