Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
21A00xxx SCSI DASD device errors
Notes:
1. Before replacing any system
components, ensure that the:
a. Controller and each device on
the SCSI bus is assigned a
unique SCSI ID.
b. SCSI bus is properly
terminated.
c. SCSI signal and power cables
are securely connected and
not damaged.
2. The location code information is
required to identify the ID of SCSI
device failures, as well as to
indicate the location of the
controller to which the device is
attached.
3. Check below for the xxx value.
The xxx can stand for anything
like 001, 002, 003 and so on.
Ensure that all components
associated with the suspected
SCSI device are thoroughly
checked.
21A00001 Test Unit Ready Failed - hardware error. Refer to the notes in error code
21A00xxx.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
21A00002 Test Unit Ready Failed - sense data
available.
Refer to the notes in error code
21A00xxx.
1. Replace the media (in removable
media devices).
2. Replace the SCSI device.
21A00003 Send diagnostic failed. Refer to the notes in error code
21A00xxx. Replace the SCSI device.
21A00004 Send diagnostic failed - DevOfl
command.
Refer to the notes in error code
21A00xxx. Replace the SCSI device.
21E00xxx SCSI tape Refer to 21A00xxx for a description
and repair action for the xxx value.
21ED0xxx SCSI changer. Refer to 21A00xxx for a description
and repair action for the xxx value.
21EE0xxx Other SCSI device type. Refer to 21A00xxx for a description
and repair action for the xxx value.
21F00xxx SCSI CD-ROM. Refer to 21A00xxx for a description
and repair action for the xxx value.
120 Service Guide