Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
25010007 Image has bad CRC. 1. Power-on the system unit.
2. Do the following flash recovery
procedure:
a. Insert a newly formatted DOS
diskette loaded with service
processor firmware into the
diskette drive. The file name
must be
spflash.img
.
b. Shut down the system unit and
unplug the power cable.
c. Plug in the power cable,
power-on the system unit.
3. Retry item 2 with a newly
formatted DOS diskette.
4. Go to “MAP 1540: Minimum
Configuration” on page 63.
25010008 Flash is write-protected, update
cancelled.
1. Turn off, turn on system unit and
retry.
2. Replace the system board.
Location: P1
(See notes on page 115.)
25010009 Flash module is unsupported or not
recognized.
Make sure correct firmware update
diskette is being used with this
system.
2501000A Flash write-protected. 1. Turn off, turn on system unit, retry.
2. Replace the system board.
Location: P1
(See notes on page 115.)
2501000C Failed write to flash memory 1. Turn off, turn on system unit, retry.
2. Replace the system board.
Location: P1
(See notes on page 115.)
25A0xxx0 L2 cache controller problem. 1. Replace the processor card.
Location: P1-C1
Location: P1-C2
Replace the system board.
Location: P1
(See notes on page 115.)
See error code 2B2xxx22 for xxx
definitions.