Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00315 Service processor reports 5 V under
voltage alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00316 Service processor reports 3.3V over
voltage alert.
1. Check, and reseat if necessary,
power connectors P1 and P2.
2. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00317 Service processor reports 3.3V under
voltage alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00318 Service processor reports 2.5 V over
voltage alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00319 Service processor reports 2.5 V under
voltage alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
Chapter 5. Error Code to FRU Index