Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00303 Service processor reports slow fan
number 4.
1. Replace fan 4.
Location: F4
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00309 Service processor reports generic cooling
alert.
1. Check for cool-airflow obstructions
to the system.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00310 Service processor reports processor card
over temperature alert.
1. Check for cool-airflow obstructions
to the system.
2. If the problem persists, replace
processor card.
Location: P1-C1
Location: P1-C2
2BA00311 Service processor reports system board
over temperature alert.
1. Check for cool-airflow obstructions
to the system.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00312 Service processor reports memory over
temperature alert.
1. Check for cool-airflow obstructions
to the system.
2. Replace the memory card.
Location: P1-M1
2BA00313 Service processor reports generic power
alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00314 Service processor reports 5 V over
voltage alert.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the power backplane.
Location: P3
3. Replace the system board.
Location: P1
(See note 3 on page 115.)