Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00104 Service processor firmware update file is
the same level as the service processor
firmware, update cancelled.
1. Obtain new level of service
processor firmware.
2. Retry operation.
2BA00200 Service processor firmware update error
occurred, update not completed.
Error occurred during service processor
flash write operation.
Service processor firmware update
error recovery procedure:
1. Turn off the system.
2. Unplug power cable and then plug
power cable back in.
3. Turn on the system.
4. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00201 Service processor firmware update error
occurred, update not completed.
Error occurred while reading service
processor CRC.
See error code 2BA00200 for
recovery procedure.
2BA00202 Service processor firmware update error
occurred, update not completed.
Error occurred while verifying service
processor firmware CRC.
See error code 2BA00200 for
recovery procedure.
2BA00203 Service processor firmware update error
occurred, update not completed.
Error occurred while reading new service
processor firmware CRC after updating
service processor firmware.
See error code 2BA00200 for
recovery procedure.
2BA00204 Service processor firmware update error
occurred, update not completed.
Error occurred while calculating firmware
CRC.
See error code 2BA00200 for
recovery procedure.
2BA00300 Service processor reports slow fan
number 1.
1. Replace fan 1.
Location: F1
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00301 Service processor reports slow fan
number 2.
1. Replace fan 2.
Location: F2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00302 Service processor reports slow fan
number 3.
1. Replace fan 3.
Location: F3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
Chapter 5. Error Code to FRU Index
135