Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00050 Service processor reports system
operator panel VPD module not present
or not recognizable.
Replace the operator panel.
Location: L1
(See note 2 on page 115.)
Note: Swap the old VPD module from
the old operator panel control
assembly to the new one.
2BA00051 System operator panel VPD data
corrupted.
Replace the operator panel control
assembly. (See note 2 on page 115.)
Note: Swap the old VPD module from
the old operator panel control
assembly to the new one.
2BA00060 Service processor reports system board
VPD module not present.
Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00061 Service processor reports system board
VPD data corrupted.
Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00062 Service processor reports system board
VPD module not present.
Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00063 Service processor reports system board
VPD data corrupted.
Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00070 Service processor reports processor card
VPD module not present.
Replace the processor card.
Location: P1-C1
Location: P1-C2
2BA00071 VPD data corrupted for processor card. Replace the processor card.
Location: P1-C1
Location: P1-C2
2BA00073 VPD data corrupted for processor card. Replace the processor card.
Location: P1-C1
Location: P1-C2
2BA00080 Service processor reports memory card
VPD module not present
Replace the memory card, location:
P1-M1.
2BA00081 VPD data corrupted on memory card Replace the memory card, location:
P1-M1.
2BA00100 Service processor firmware recovery
information could not be written to
diskette.
1. Check diskette media write-protect
tab.
2. Replace the diskette drive.
2BA00102 No service processor update diskette in
drive.
Insert the diskette.
2BA00103 Service processor firmware update file is
corrupted, update cancelled.
1. Obtain new service processor
firmware diskette.
2. Retry operation.
134 Service Guide