Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00012 Service processor reports self-test failure. 1. Unplug the system power cable
and wait until the system power
indicator remains off and the
operator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00013 Service processor reports bad NVRAM
CRC.
1. If problem persists, replace
battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00014 Service processor reports bad service
processor firmware.
Use service processor firmware
diskette to reprogram firmware.
2BA00017 Service processor reports bad or low
battery.
1. Replace the battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00018 EPOW test failure. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00019 IRQ13 test failure. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00024 Service processor reports bad power
controller firmware.
Use the system firmware diskette to
reprogram the system firmware.
2BA00040 Service processor reports service
processor VPD module not present.
1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00041 Service processor VPD is corrupted. 1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)