Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00337 Service processor reports memory critical
over temperature slow shutdown request.
1. Check for cool-airflow obstructions
to the system.
2. Check fans for obstructions that
prevent them from normal
operation (example: a cable
caught in the fan, preventing it
from spinning)
3. If problem persists, replace the
memory card.
Location: P1-M1
2BA00338 Service processor reports generic fast
shutdown request.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00340 Service processor reports locked fan -
fast shutdown request fan number 1.
1. Replace fan 1.
Location: F1
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00341 Service processor reports locked fan -
fast shutdown request fan number 2.
1. Replace fan 2.
Location: F2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00342 Service processor reports locked fan -
fast shutdown request fan number 3.
1. Replace fan 3.
Location: F3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00343 Service processor reports locked fan -
fast shutdown request fan number 4.
1. Replace fan 4.
Location: F4
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00350 Service processor reports generic
immediate shutdown request.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
Chapter 5. Error Code to FRU Index
139