Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
2BA00351 Service processor reports generic AC
power loss EPOW.
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00352 Service processor reports loss of AC
power (outlet).
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00353 Service processor reports loss of AC
power (power button).
1. Replace the power supply.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
2BA00356 Service processor reports fan failure in a
power supply
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
2BA00357 Service processor reports
over-temperature condition in a power
supply
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
2BA00358 Service processor reports redundant
power supply failure
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3.
2BA00399 Service processor reports unsupported
value in EPOW.
1. Check EPOW cabling on SCSI or
SSA backplanes.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)