Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
40100005 Loss of system power detected.
1. Possible temporary AC power loss.
Turn on the power. If the system
boots, use the AIX Service Aids to
reset the System Attention
indicator and the Lightpath
indicators. On your next shutdown
and prior to reboot, use the
service processor menus to reset
the error log.
2. If AC power is available to system,
replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
40100006 Loss of ac power to system detected.
1. Possible temporary AC power loss.
Turn on the power. If the system
boots, use the AIX Service Aids to
reset the System Attention
indicator and the Lightpath
indicators. On your next shutdown
and prior to reboot, use the
service processor menus to reset
the error log.
2. If AC power is available to system,
replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
40100007 Immediate shutdown due to loss of AC to
system.
1. Possible temporary AC power loss.
Turn on the power. If the system
boots, use the AIX Service Aids to
reset the System Attention
indicator and the Lightpath
indicators. On your next shutdown
and prior to reboot, use the
service processor menus to reset
the error log.
2. If AC power is available to system,
replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
Chapter 5. Error Code to FRU Index
141