Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
460000C5 Mezzanine/system bus address parity
error. (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000C6 Mezzanine/system bus data parity error.
(checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000C7 Mezzanine/system bus time-out, transfer
or protocol error. (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000D4 I/O expansion bus data parity or CRC
error (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000D5 I/O expansion bus data time-out, access
or other error. (checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000D6 I/O expansion bus connection failure.
(checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
460000D7 I/O expansion bus unit is not in an
operating state (power down, off-line).
(checkstop)
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
Chapter 5. Error Code to FRU Index