Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
460000D8 A generic memory controller
detected-checkstop has occurred.
1. Try to reboot the system into
online diagnostics service mode to
preserve the AIX error log. Run
diagnostics in problem
determination mode to determine
the cause of the failure. If a new
SRN or error code is generated,
follow the actions for that code.
2. Try to boot AIX diagnostics from
CD-ROM.
a. If the boot is successful, run
advanced diagnostics and
follow the actions for any SRN
or error code that is generated.
If the same error code is
generated, go to “MAP 1540:
Minimum Configuration” on
page 63.
b. If AIX standalone diagnostics
do not boot, follow the actions
for any new SRN or error code
that is generated. If the same
error code is generated, go to
“MAP 1540: Minimum
Configuration” on page 63.
164 Service Guide

Table of Contents

Related product manuals