Table 3. Firmware Error Codes. (continued)
Error Code Description Action / Possible Failing FRU
4B200060 The processor cards are not properly
seated
1. Reseat the processor cards.
Location: P1-C1
Location: P1-C2.
2. Remove the power cord from the
system. If both processor cards
are installed, remove the second
card and reapply power. If the
problem is fixed, replace the
second card. If the problem is not
fixed, replace the first processor
card with the second processor
card that was just removed and
reapply power. If the problem is
fixed, replace the processor card
that was in the first slot.
3. Replace the system board.
Location: P1
4B201010 A machine check has occurred. 1. Attempt to reboot the system into
online diagnostics. If the reboot
fails, attempt to boot from a
CD-ROM. If the reboot is
successful, run diagnostics in
problem determination mode to
determine the cause of the
problem.
2. Go to “MAP 1540: Minimum
Configuration” on page 63.
4B201020 TEA Error Go to MAP 1540: Minimum
Configuration, “Step 1540-24” on
page 81.
4B276851 Processor BIST failed Replace the processor card.
Location: P1-C1.
Location: P1-C2