Symptom Action
The system stopped and a POST indicator is
displayed on the system console and an 8-digit
error code is not displayed.
If the POST indicator represents:
v Memory, record error code M0MEM002.
v Keyboard, record error code M0KBD000.
v SCSI, record error code M0CON000.
v Network, record error code M0NET000.
v Speaker (audio), record error code
M0BT0000.
Go to “Step 1020-3” on page 47.
The system stops and a 4-digit number is
displayed in the operator panel display.
If the number displayed has the format ″E0xx″,
then go to “Service Processor Checkpoints” on
page 86. If the number is in the range of
″E1xx-EFFF″ then go to “Firmware
Checkpoints” on page 92.
For all other numbers, record SRN 101-xxx,
where xxx is the last three digits of the
four-digit number displayed in the operator
panel, then go to the ″Fast Path MAP″ in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
Note: If the operator panel displays 2 sets of
numbers, use the bottom set of numbers as the
error code.
The System Management Services is
displayed.
Go to “Step 1020-4” on page 48.
All other symptoms. If you were directed here from the Entry MAP,
go to “MAP 1540: Minimum Configuration” on
page 63. Otherwise, find the symptom in the
“Quick Entry MAP” on page 36.
46 Service Guide