146 IBM System Storage N series Hardware Guide
14.Boot the nodes by entering the following command on either node:
boot_ontap
15.Verify that you correctly replaced the SAS cables by entering the following command on
the console of either node:
sysconfig
The output should be the same as Step 2: the system should be Multi-Path HA. However,
the SAS ports and attached disk shelf information changed because disk shelves were
moved from FC ports (connected through the bridges) to SAS ports on the controllers.
16.Enable controller failover by entering the following command on either node:
cf enable
17.Verify that controller failover is enabled by entering the following command on either node:
cf status