40  IBM System Storage N series Hardware Guide
4.3.3  N7x50T cooling architecture
The N7x50T cooling architecture includes the following features:
ň° Six fan FRUs per chassis, which is paired three each for top and bottom bays (each fan 
FRU has two fans)
ň° One failed fan is allowed per chassis bay:
â Controller can run indefinitely with single failed fan
â Two failed fans in controller bay cause a shutdown
â Two-minute shutdown rule applies if a fan FRU is removed: Rule that is enforced on a 
per-controller basis
4.3.4  System-level diagnostic procedures
The following system-level tools are present in N7x50T systems:
ň° SLDIAG replaces SYSDIAG: Both run system-level diagnostic procedures
ň° SLDIAG has the following major differences from SYSDIAG:
â SLDIAG runs from maintenance mode: SYSDIAG booted with a separate binary
â SLDIAG has a CLI interface: SYSDIAG used menu tables
ň° SLDIAG used on all new IBM N series platforms going forward
4.3.5  MetroCluster, Gateway, and FlexCache 
MetroCluster and Gateway configurations include the following characteristics:
ň° Supported MetroCluster two-chassis configuration
ň° Single-enclosure stand-alone chassis: IBM N series N7950T-E22 controller with IOXM
ň° Fabric MetroCluster requires EXN4000 shelves
ň° The N7x50T series can also function as a Gateway
ň° FlexCache uses N7x50T chassis:
â Controller module (and in IOXM for N7950T)
â Supports dual-enclosure HA configuration
4.3.6  N7x50T guidelines
The following tips are useful for the N7x50T model:
ň° Get hands-on experience with Data ONTAP 8.1
ň° Do not attempt to put vertical slot I/O system boards in horizontal expansion slots
ň° Do not attempt to put expansion cards in vertical I/O slots
ň° Onboard 10 GbE ports require feature code for SFP+: Not compatible with other SFP+ for 
the two-port 10 GbE NIC (FC 1078)
ň° Onboard 8 Gb SFP not interchangeable with other SFPs: 8 Gb SFP+ autoranges 8 Gbps, 
4 Gbps, and 2 Gbps; does not support 1 Gbps
ň° Pay attention when 6 Gb SAS system board in I/O slot 1
ň° NVRAM8 and SAS use QSFP connection