8
OTHER FUNCTIONS
8-6
REF adjustment
The IC-905 automatically adjusts the internal
reference frequency using the received GPS data as
the default setting�
L The IC-905 automatically adjusts the internal reference
frequency, regardless of the “Position Input” setting�
NOTE: The transceiver has been adjusted and
tested at the factory before being shipped� You
should not have to manually recalibrate it�
To manually adjust the internal reference frequency:
1� Display the “REF Adjust” screen�
»
SET > Function > REF Adjust
2� Touch [Cancel Sync]�
3� Touch [YES]�
4� Adjust the internal reference frequency
5� To close the REF Adjust screen, push
several times�
L Information
To synchronize to GPS again, touch [Sync to GPS] in
Step 3�
While synchronizing, “REF Adjust (Synchronizing to
GPS)” is displayed, and you cannot manually adjust the
internal reference frequency
The GPS synchronization is not automatically canceled,
even if you turn OFF the transceiver, then turn it ON
again�
NOTE: Sudden changes of temperature, for
example, when you turn ON the transceiver, or start
transmission, may cause the transceiver to take a
longer time to synchronize�