9-1
Scan types
Basic scanning
SCAN TYPE SCANNING DETAILS
VFO SCAN
PROGRAMMED SCAN
Repeatedly scans between 2 Scan Edge frequencies of Program Scan Edge memory
channels. The scan starts from the lower edge frequency. (p.9-4)
FINE PROGRAMMED
SCAN
During a Programed scan, the scan speed decreases when the squelch opens, but the
receiver keeps scanning. The scan tuning step changes to 10 Hz when the squelch opens.
F SCAN
Repeatedly scans within the F span area. The scan starts from the center frequency, then
upper edge and lower edge. (p.9-5)
FINE F SCAN
During a F scan, the scan speed decreases when the squelch opens, but the receiver
keeps scanning. The scan tuning step changes to 10 Hz when the squelch opens.
AUTO MEMORY WRITE
SCAN
During a Programed scan, and when a signal is received, the frequency is automatically
stored into an Auto Memory Write channel group. (p.9-6)
MEMORY SCAN
MEMORY SCAN
Repeatedly scans memory channels, including Skip and Auto Write memory channels.
You can select the group and the scan edge channel.
(p.9-7)
SELECT MEMORY SCAN
Repeatedly scans all or one of 9 Select Memory channels. (p.9-7)
MODE SELECT MEMORY
SCAN
Repeatedly scans the memory channels with the selected receive mode (ignoring other
receive modes). (p.9-9)
PRIORITY SCAN
Periodically monitors a selected memory channel while receiving a signal on VFO. (p.9-2)
Adjusting the scan speed
Adjust the scan speed for slower or faster scans.
1. Push .
The setting menu opens.
2. Touch [SCAN SPEED].
3. Rotate .
Setting range: 1 (slow) ~ 30 (fast)
L You cannot change the scan speed during a Fine
Program scan or Fine ∂F scan.
Push to start or stop a scan, then touch the
desired scan type.
L
See the following pages for the Scan setting details. (p. 9-3)
D VFO scan and Memory scan
1. Push .
If you started a scan of the same scan type before, hold
down
for a second, to start the same scan.
2. Touch the desired scan type.
The SCAN screen opens, and the scan starts.
L
Rotating changes the scan direction:
Rotate right for the up scan, rotate left for the down scan.
L To cancel the scan, push .
L You can hide the SCAN screen during a scan. Set
[Display SCAN Screen (at SCAN START)] item to
"OFF" on the SCAN SETTING screen. (p. 9-3)
SCAN START screen
D Priority scan
Follow the procedure below to start or stop a Priority scan..
LSee page 9-2 for setting priority channel.
1. Push .
"PRIO" is displayed.
L Hold down
for 1 second to monitor the priority
channel.
2. Push again to cancel the scan.