9-2
Priority scan
A priority scan periodically checks a selected memory
channel* while receiving on a VFO frequency.
* Memory channel, Auto Memory Write channel, Scan Skip
Channel or Program Scan Edge Channel.
D Priority scan operation
1. Open the SCAN screen.
MENU
» SCAN
2. Touch [TYPE/SET].
3. Touch [PRIO].
4. Touch [SELECT] to select the item to change.
No.: Priority memory preset number (0 ~ 9)
(You can save up to 10 pairs of Group and Ch.)
Group: Memory Group number
Ch: Memory channel number.
5. Rotate to change the setting.
LYou cannot select blank channels.
6. Touch [SELECT] several times to exit the edit
mode, then touch [START] or push .
A Priority scan starts.
To cancel the scan, push
or touch [STOP].
7. To close the SCAN screen, push .
D Monitoring the Priority channel
z During a Priority scan, hold down for
1 second to monitor the priority channel.
"PRIO" is displayed while monitoring.
Push
to cancel the monitoring.
Setting the Scan Resume function
D Setting the Scan Resume function
You can set the Scan Resume options for when the
signal disappears.
1. Hold down for 1 second.
The SCAN DELAY screen opens.
2. Touch the resume condition option.
[OFF]: The scan pauses until the signal
disappears.
[DELAY]: When a signal is received, the
scan pauses for the preset delay
period, then resumes.
(Set the delay by rotating .)
[](Innity): Thescaniscancelledwhena
signal is received.
D Setting the scan delay timer
You can set the delay time that the scan restarts after
the signal disappears.
z Rotate .
Setting range: 1 ~ 30 seconds
LThe delay amount is displayed while setting.
L If a signal is received before the delay time has
expired, the timer restarts.
L When the Scan Resume function is set to [OFF] or [],
the scan delay is not activated.
90.6 MHz (VFO)
Blinks
SCAN screen
Setting the priority interval
Priority scan checks the priority channel according to
the set interval.
1. Push .
The setting menu opens.
2. Touch [PRIO INTVL].
3. Rotate .
Setting range: 1 ~ 15 seconds
9
SCANS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
(Example)
145 MHz (Memory channel)