Step 4 settings
Step 5 settings
Function Device Address Setting Value Details
Steady pulse frequency D0026, D0027 5000 5,000 Hz
Frequency change time D0029 8000 8,000 ms
Preset value D0030, D0031 1000000 Preset value=1,000,000
Control direction D0032
Acceleration/deceleration control D0032 Acceleration/deceleration later After=2
Next step number D0033 5 Step 5
Function Device Address Setting Value Details
Steady pulse frequency D0034, D00035 15 15 Hz
Frequency change time D0037 8000 8,000 ms
Preset value D0038, D0039 100000 Preset value=100,000
Control direction D0040
Acceleration/deceleration control D0040 Acceleration/deceleration later After=2
Next step number D0041 0 0=End output