24: C
LOCK
I
NSTRUCTIONS
24-8 FC6A S
ERIES
MICROS
MART
L
ADDER
P
ROGRAMMING
M
ANUAL
FC9Y-B1726
Source 2
30
D100
(Hour)
40
D101
(Minute)
50
D102
(Second)
When the result is less than 00:00:00, 24 is added to the result, and the day data is decremented.
Source 1
7
D8008
(Year)
8
D8009
(Month)
23
D8010
(Day)
Destination 1
20
D8012
(Hour)
30
D8013
(Minute)
40
D8014
(Second)
4
D8011
(D of W)
7
D200
(Year)
8
D201
(Month)
22
D202
(Day)
13
D204
(Hour)
49
D205
(Minute)
50
D206
(Second)
3
D203
(D of W)
(Note)
Note: D8011 in source 1 is not used for execution and does not need to be designated. The day of week is calculated automatically from the
resultant year, month, and day, and stored to D203 of destination 1.