10 - 28
IPN 074-505-P1E
IC6 Operating Manual
19
(0x13)
Rise Time 2
(seconds)
(mm:ss)
0/ 5999/ 0
0/ 99:59/ 0
Time
See Time Note
20
(0x14)
Soak Time 2
(seconds)
(mm:ss)
0/ 5999/ 0
0/ 99:59/ 0
Time
21
(0x15)
Auto Soak 2 0/ 1/ 0 Encode 0 = No
1 = Yes
22
(0x16)
Dep After Pre-Dep 0/ 1/ 1 Encode 0 = No
1 = Yes
23
(0x17)
Delay Option 0/ 3/ 0 Encode 0 = None, 1 = Shutter
2 = Control, 3 = Both
24
(0x18)
Control Delay Time
(seconds)
(mm:ss)
0/ 5999/ 0
0/ 99:59/ 0
Time See Time Note
Gray font unless Delay
option is set to control
or both.
25
(0x19)
Shutter Delay Accur
(%)
1/ 99/ 5 Integer Gray font unless Delay
option is set to shutter
or both.
26
(0x1a)
Transfer Sensor 0/ 8/ 0 Integer 0 = No transfer sensor.
Gray font unless delay option is set to shutter or both
and transfer service is not set to 0. Update not
allowed if material is running.
27
(0x1b)
Transfer Tooling
(%)
1.0/ 999.9/
100.0
REAL_4X1
28
(0x1c)
Feed Power
(%)
0.0/ 99.99/
0.0
REAL_4X2
29
(0x1d
Feed Ramp Time
(seconds)
(mm:ss)
0/ 5999/ 0
0/ 99:59/ 0
Time See Time Note
30
(0x1e)
Feed Time
(seconds)
(mm:ss)
0/ 5999/ 0
0/ 99:59/ 0
Time See Time Note
Table 10-9 Material parameters (continued)
QM
&
UM
Cmnd
ID
Name
(Units)
Range:
Low Limit/
High Limit/
Default
Data Type
Notes
Update Restrictions
and Display Notes