10 - 51
IPN 074-505-P1E
IC6 Operating Manual
24
(0x18)
Clear Failed
Crystals X
<Byte> Clears all failed crystals except the current crystal for the
requested sensor. X = Sensor
25
(0x19)
Reserved for future use.
26
(0x1a)
Rotate head X <Byte> If the requested sensor is a multi crystal sensor and the
IC6 is in Ready, Stop or all active layers are in Idle or
Suspend, the sensor head will rotate. X = Sensor
27
(0x1b)
Default all
Parameters
Sets all parameters except the communication
parameters to default values.
28
(0x1c)
Default Process
<Process#>
<Byte> # Range is 1 to 50
Removes all layers of the specified process.
29
(0x1d)
Soak Hold Pre Con
on <Material >
<Byte>
Material Range is 0 - 32 (0 = All Materials)
30
(0x1e)
Soak Hold Pre Con
off <Material >
<Byte>
31
(0x1f)
Start Inhibit On Disallows a Start command to be executed.
32
(0x20
Start Inhibit Off Allows a Start command to be executed.
33
(0x21)
RateWatcher
Sampling Inhibit
On <Material >
<Byte> Will immediately cause the Deposit state to leave
sampling and not return until turned off.
34
(0x22)
RateWatcher
Sampling Inhibit
Off <Material >
<Byte> Allows the Deposit state to go into the RateWatcher
algorithm.
35
(0x23)
RateWatcher
Sample Initiate On
<Material >
<Byte> Allows the Deposit state to enter RateWatcher sampling
Table 10-15 Remote general (continued)
RG
Command
ID
Meaning
Action Value Notes