Fault Correction Procedure
249
062 EXHAUST FAN CHECK
SEE USERS MANUAL
Yes Sensors cannot
detect current in fan
circuit.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your
InfoPrint service
representative. NOTE:
This message should not
appear on a Pedestal
model. If this message
does appear, contact your
InfoPrint Service
Representative.
065 HAMMER FAN CHECK*
SEE USERS MANUAL
Yes Sensors cannot
detect current in fan
circuit.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your
InfoPrint service
representative.
069 DATA CLEARED N/A Appears when data is
cleared out of printer
after Cancel key has
been pressed.
No action required.
080 POWER SUPPLY HOT No Power supply
temerature is elevated
beyond normal
threshold.
Contact your InfoPrint
service representative.
081 POWER VOLT CHECK*
SEE USERS MANUAL
No Power supply voltage
failure.
Contact your InfoPrint
service representative.
082 POWER 8.5V CHECK*
SEE USERS MANUAL
No Internal power failure. Contact your InfoPrint
service representative.
Table 9: Fault Messages