104 Event type
Centrali anti-intrusione
Valid code at keypad
Valid Code AtKeyp.
An entered user-code PIN is recognized
as valid on the keypad
One event for each
keypad
Yes
Valid key at reader
ValidKeyAtReader
A key used at a reader is recognized as
valid on the reader
One event for each
reader
Yes
Valid user-code on
partition
Partition code
An entered user-code PIN is recognized
as valid on the partition
One event for each
partition
Yes
Valid key on partition
Partition key
A key used at a reader is recognized as
valid on the partition
One event for each
partition
Yes
Failed call
Failed call
All attempts to call a specific telephone
number have failed
One call to the phone number has
been successful
One event for each
contact telephone
number
no
Timer activated
Timer activated
The timer is enabled (On) The timer is disabled (Off)
One event for each
timer
no
Thermostat on keypad
Thermostat ON
The activation conditions set for the key-
pad thermostat occur.
The deactivation conditions set
for the keypad thermostat occur.
One event for each
keypad
no
Activate scenario
Scenario ON
The status of all the partitions corre-
sponds exactly to the pre-set scenario.
The status of all least one of the
partitions does not correspond to
the pre-set scenario.
One event for each
scenario
no
Programmable event
ProgrammableEvt
See paragraph 12-5 Programmable events no
Emergency button
Emergency button
One of the emergency-buttons is pressed
One event for each
emergency-button
Yes
Panic
Panic Panic
The “Panic” shortcut has been activated. 15 Yes
Periodic event
Periodic event
The Periodic Event occurs 4 Yes
Open-panel tamper
Control panel open
The control-panel enclosure is removed
The front of the control-panel is
replaced
1no
Dislodged-panel tam-
per
Dislodged panel
The control-panel enclosure is detached
from the wall
The control-panel enclosure is
reattached to the wall
1no
Zone fuse fault
Zone fuse fault
The zone protection fuse on the control
panel is not operational (blown)
The zone protection fuse on the
control panel restores
1no
I-BUS fuse fault
IBUS fuse fault
The I-BUS protection fuse is not opera-
tional (blown)
The I-BUS protection fuse
restores
1no
Battery fault
Low battery
The backup battery is low
(voltage below 10.4V)
The backup battery is charged
(voltage above 11.4V)
1no
Mains failure
Mains failure
The primary power supply 230V~ fails
The primary power supply 230V~
is restored
1no
Expansion tamper
Expansion tamper
An expansion board signals tamper condi-
tions
Tamper conditions clear on all the
system expansion boards
1no
Keypad Tamper
Keypad tamper
A keypad signals tamper conditions
Tamper conditions clear on all the
system keypads
1no
Reader Tamper
Reader tamper
A reader signals tamper conditions
Tamper conditions clear on all the
system readers
1no
Sounder flasher tam-
per
Sound.flash.Tamp
Tamper conditions on a sounder/flasher
on the BUS
All the sounder/flashers on the
BUS reset
1no
Nexus tamper
Nexus tamper
The GSM dialer Nexus signals tamper
Tamper conditions clear on the
Nexus
1no
LIVPWR100 tamper
Tamp. LIVPWR100
For future use
Video detector tamper
VideoSens.Tamper
For future use
I/O expansion loss
Expansion loss
An expansion board cannot be found on
the BUS
All expansion boards can be
found on the BUS
1no
Keypad Loss
Keypad loss
A keypad cannot be found on the BUS
All keypads can be found on the
BUS
1no
Reader Loss
Reader loss
A reader cannot be found on the BUS
All readers can be found on the
BUS
1no
Sounder/flasher loss
Sound.flash.Loss
A sounder/flasher cannot be found on the
BUS
All sounder/flashers can be found
on the BUS
1no
Nexus loss
Nexus loss
The control panel is unable to communi-
cate the Nexus 100
Communication between the con-
trol panel and the Nexus restores
1no
LIVPWR100 loss
Nexus LIVPWR100
For future use
Video detector loss
VideoSensor loss
For future use
Jamming
Jamming
Wireless interference detected Wireless interference cleared 1 no
Low battery on wire-
less zone
Low battery WLS
The battery of a least one wireless detec-
tor is running low
All the wireless detectors are run-
ning with sufficient power
1no
Wireless zone loss
WLS zone loss
Loss of at least one wireless detector has
been signalled (supervisory time expired)
All the wireless detector are pres-
ent
1no
Valid Installer code
Installer code
An Installer PIN entered at a keypad is
recognized as valid
1Yes
Invalid code
Invalid code
An invalid code PIN is entered at a key-
pad
1Yes
False key
False key
An invalid key is used at a reader 1 Yes
Nexus fault
Nexus fault
The Nexus device signals a fault (refer to
the <User manual)
Fault conditions clear on the
Nexus
1no
Telephone line down
Tel. line down
The land line is not working The land line restores 1 no
Hard reset
Hard reset
The control panel re-initializes. The sys-
tem clock may be wrong or not working
properly.
1Yes
Call queue full
Call queue full
There are no more slots left in the outgo-
ing call queue
1Yes
Name Occurs when... Restores when ... Number of events