Programming manual
Event type 105
Successful call
Successful call
The call is answered 1 Yes
Input undergoing pro-
gramming
Programming
Access to system programming is autho-
rized
End of system programming 1 no
Ongoing call
Ongoing call
A call is sent A call ends 1 no
SMS message not
delivered
SMSMessageFailed
Nexus failed to send SMS message 1 Yes
Output fault
Output fault
An output fails to switch status as com-
manded
1Yes
Low credit
Low credit
The credit remaining on the SIM card
inserted in the Nexus is below the mini-
mum credit threshold.
The remaining credit is above the
minimum credit threshold.
1no
Date and time change
Time modified
There is a change in the date and time.
This event will be recorded together with
the date/time before the change.
There is a change in the date and
time.
This event will be recorded
together with the date/time after
the change.
1no
Resistance internal
battery
Int. Resistance
The internal resistance of the battery has
exceeded the R
i max
value.
The internal resistance of the
battery returned to below the R
i
max
value.
1no
Battery short-circuit
Battery shorted
A short-circuit condition has been
detected on the battery connection termi-
nals
The short-circuit condition is no
longer present
1no
Battery disconnection
Battery disconn.
The backup battery is disconnected The backup battery is connected 1 no
Power-supply over-
load
PwSupplyOverload
Output overload is detected on the
power-supply unit
The electrical load returns below
the allowed limit
1no
Overheating on
power-supply unit
PwSupply Overheat
The temperature of the power-supply unit
has exceeded the allowed limit
The temperature of the power-
supply unit is normal
1no
Ground fault
Ground fault
Leakage to ground is present
The leakage to ground condition
is no longer detected
1no
Overvoltage output
“x”
Overvoltage ?x?
A voltage of over 14.5V has been
detected on terminal “
+AUX
” corre-
sponding to number “x” on the mother-
board.
The normal voltage on the termi-
nal has been restored.
one for each output
“
+AUX
” of the
motherboard
no
Overvoltage BUS
Overvolt. BUS
A voltage of over 14.5V has been
detected on I-BUS terminal “+” on the
motherboard.
The normal voltage on the termi-
nal has been restored.
1no
Low voltage output
“x”
Low voltage "x"
A voltage below 9.8V has been detected
on terminal “
+AUX
” corresponding to
number “x” on the motherboard.
The normal voltage on the termi-
nal has been restored.
one for each output
“
+AUX
” of the
motherboard
no
Low voltage output
BUS
Undervoltage BUS
A voltage below 9.8V has been detected
on I-BUS terminal “
+
” on the mother-
board.
The normal voltage on the termi-
nal has been restored.
1no
Short-circuit output
“x”
Short circuit ?x?
A short-circuit has been detected on ter-
minal “
+AUX
” corresponding to number
“x” on the LIVPWR100 board.
The short-circuit is no longer
present.
one for each output
“
+AUX
” of the
motherboard
no
Short-circuit output
BUS
Short circuit BUS
A short-circuit has been detected on I-
BUS terminal “
+
” on the motherboard.
The short-circuit is no longer
present.
1no
Overload output “x”
Overload ?x?
A load of over 1.5A has been detected on
terminal “
+AUX
” corresponding to num-
ber “x” on the motherboard.
The terminal restores to normal.
one for each output
“
+AUX
” of the
motherboard
no
Overload output BUS
Overload BUS
A load of over 3.5A has been detected on
I-BUS terminal “
+
” on the motherboard.
The terminal restores to normal. 1 no
Failed communication
with power-supply
unit
NoCommunPwSupply
Communication between the power sup-
ply unit and the control panel has broken
down.
Communication between the
power supply unit and the control
panel restores.
1no
Telephone call on
Number 1 in progress
Tel. on number 1
A call has been sent to phone number 1
The call has ended (even in the
event of negative outcome)
1no
Telephone call on
Number 15 in progress
Tel.on number 15
A call has been sent to phone number 15
The call has ended (even in the
event of negative outcome)
1no
Data synchronization
between control panel
and IP2RX
Sync.data IP2RX
For future use
IP connection lost
GPRS conn. lost
The IP connectivity test is enabled and
the test result in negative (failed).
A connection attempt has been
successful.
1no
GPRS connection lost
GPRS conn. lost
Nexus has detected GPRS connectivity
trouble.
The GPRS connectivity is
restored.
1no
Dust in smoke detec-
tor chamber
Detector dusty
The smoke chamber of at least one of the
Air2-FD100 smoke detectors is contami-
nated by dirt or dust.
Refer to the instructions supplied with the
detector for information regarding the
respective threshold.
All smoke sensors have stopped
signalling the presence of dust.
1no
General alarm
Alarm
Any one of the zones has generated an
alarm signal.
All the zones have reset the
alarm signal.
1no
General tamper
Tamper
Any one of the zones has generated a
tamper signal.
All the zones have reset the tam-
per signal.
1no
Name Occurs when... Restores when ... Number of events
Pulse
events