106 Combination of outputs triggered by events
Centrali anti-intrusione
Appendix
G
Combination of outputs triggered by events
This appendix explains the behaviour of the outputs programmed in the “Outputs” and “Other
outputs” parameters of each event together with the activation and deactivation modes
(“Tone types” parameter) of the sounder/flashers on the BUS.
Tabella G-1: Output typology
Symbol/Initials Description
TM
Output on terminal/Relay/OC1/OC2 - monostable
TB
Output on terminal/Relay/OC1/OC2 - bistable
SM
Sounder/flasher output with limited flasher time
SB
Sounder/flasher output with unlimited flasher time
Tabella G-2: Functioning and deactivation of the outputs
Symbol/Initials Description
A
These outputs will deactivate if a Stop alarm, Reset partition or Disarm operation is carried out while the monostable time
of the main output is running.
B
These outputs will deactivate only when the event clears after expiry of the monostable time of the main output.
C
These outputs, due to the continuous flasher function, will not deactivate automatically.
After the expiry of the monostable time on the main output, to switch off the SB flashers on the alarm signalling devices,
it is necessary to:
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
D
These outputs will deactivate only when the event clears.
E
These outputs will deactivate if, when an event is active, a Stop alarm operation, reset or disarm partition command oper-
ation is carried out.
F
These outputs, due to the continuous flasher function, will not deactivate automatically. In order to deactivate the SB
flashers of the device on termination of the event, you must:
trigger an event which applies a Stop pattern to the SB flashers
reset the partition
G
These outputs will deactivate when the respective monostable time expires
Tabella G-3: Output combinations
Event groups
Principal output Other outputs
TM TB SM SB TM TB SM SB
Zone Alarm
terminal tamper
partition alarm
partition tamper
A G A G A B A G A C
D E E G D G E G F
A G A G A B A G A C
FE GD GE GF
Control panel open
Dislodged panel
Expansion tamper/loss
Keypad tamper/loss
Reader tamper/loss
Sounder/flasher tamper/loss
Jamming
Wireless zone loss
Telephone line down
A G A G A D A G A C
D E E G D G E G C
A G A G A B A G A C
FE GD GE GC
other events
GGBGC
DGDGF
GGBGC
FGCGC