12 Programming peripherals
Centrali anti-intrusione
KEYPAD SETTINGS
The keypads of the Prime system also provide a section where you can set their parameters,
for the customization and optimization of their use.
The complete description of the parameters in this section can be found in
paragraph 6-6-8
Keypad settings
in the user manual.
3-1-3
Keypad parameters
Table 3-1: Parameters common to all keypads
Parameter Software section Installer menu section
Wrong PIN key-
pad lockout
If a wrong code is typed-in at a keypad more than 5
times in succession, the keypad will lock for 10
minutes.
If you reset the control panel or access programming
while the keypad-lockout time is running, it will
refresh to zero and start again.
Keypad parameters
Parameters,
Keypad lockout
View open zones
The keypad will show the descriptions of any open
zones (zones which are not in standby status) when
the partitions disarm.
Any autobypassable open-zones will be shown in
white on a black background.
View open zones
Show scenario
The second line on the keypad displays will show the
description of the active scenario.
Show scenario
Message repeti-
tions on voice
keypad
This refers to the number of times messages relating
to the events are played vocally on the keypad (only
for keypads with speakers).
The playback phase can be stopped by pressing any
button.
Parameters, Other pa-
rameters,
LocKpadMessTimes
Press any key to
end playback
If this option is enabled, message playback can be
interrupted solely by pressing a button on the
keypad.
LocKpadMessTimes,
"255"
Table 3-2: Parameters for single keypads
Parameter Software section Installer menu section
Description
Description of the keypad (to be customized by the
installer).
Configured keypads ,
selected keypad
Keypads, ChoosePeriph-
eral, "keypad"
Keypad type
Check box for the selection of the keypad type:
• Keypad with display and keys
• Touch-screen keypad
•Wireless keypad
Not available
Partitions
Section for the selection of the partitions the keypad
can operate on.
Configured keypads ,
selected keypad,
General
Keypads, ChoosePeriph-
eral, "keypad"
Shortcuts
For each key, from F1 to F12, you can program the
shortcut type which can be selected from among all
the available shortcuts.
When programming an Alien keypad, positions F1 -
F12 refer to the positions in the list available in the
“Scenarios” section of the Alien keypad you are
working on.
Configured keypads ,
selected keypad,
General, Advanced
Keypads, ChoosePeriph-
eral, "keypad",
F1/4KeyShortcuts
Shortcut param-
eter
You must specify a further parameter for each
shortcut:
• Arm/Disarm - the parameter this shortcut refers
to will be one of the scenarios.
• Activate output - the parameter this shortcut
refers to will be one of the scenarios.
• Deactivate output - the parameter this shortcut
refers to will be one of the scenarios.
• Panic - the parameter this shortcut refers to will
be one of the scenarios.
Shortcut Func.keys,
"Fx", Type
Shortcut options
Shortcut Func.keys,
"Fx", Options
Requires code
If this option is enabled and a user selects the
shortcut (by pressing the relative function key), the
system will request entry of a user code before the
activating the shortcut in question. If the system
recognizes the entered user code, it will activate the
shortcut command.
Requires code