Programming manual
Programming peripherals 13
Note
The “Listen-in” and “Arming status” shortcuts will have no effect if requested at a keypad.
If you are programming an Alien keypad, the only type of shortcut that functions is “Arm/disarm”.
TOUCH-SCREEN
KEYPADS
The process of programming the graphic interface and maps on the Alien keypad must be
done through the Prime/STUDIO software program.
Once you have selected the keypad you must select “Touch keypad” as its type. The “General”
section, which is the same for all keypad types, appears with the following sections:
Alien graphics”, for the graphic interface setup (backgrounds, buttons, icons)
Alien maps”, for the configuration of the graphic maps which are accessed through the
“Maps” option in the APPs” section
Chapter 20 Graphic map configuration
.
Code entry in the
event of secu-
rity risk
if this option is enabled and the selected shortcut
involves a scenario that disarms a partition, or
switches a partition from Away mode to Stay mode,
the security of your system will obviously be at risk,
therefore, the system will request entry of a valid
code.
SecurityRiskCode
Requires confirm
operation
If this option is enabled when the user selects the
shortcut via the relative function key, the system will
request confirmation before actually activating the
shortcut, confirmation is achieved by simply pressing
the key. This option helps the user avoid accidental
activations.
This option is not available for Alien keypads.
Confirm
Temperature
hysteresis
Enter the value of the hysteresis for the “Air
conditioning” function of the selected keypad (if
enabled).
The entered value must be expressed in °C decimals
(from a minimum of 0 to a maximum of 4).
Keypads, ChoosePeriph-
eral, "keypad"
Disable tem-
perature reading
If this option is enabled, the room temperature will
not be flashed on the display. This option is valid only
for keypads equipped with thermometers.
Keypads, ChoosePeriph-
eral, "keypad", Op-
tions,
Temperature off
Disable entry-
time signal
This option enables/disables the buzzer during
partition entry-time
NoEntryTimeSign.
Disable audible
exit-time signal
This option enables/disables the buzzer during
partition exit-time
NoExitTimeSignal
Audio signal on
terminal T1 out-
put
This option enables/disables the buzzer when
terminal T1 on the keypad is activated as an output.
Beep on output
Disable chime
This option enables/disables the buzzer that signals
the violation of the bell zone of the keypad.
Disable Chime
LED OFF in
stand-by
If enabled, in the event of inactivity on the keypad for
at least 40 seconds, the respective LEDs will go off.
LED OFF in standby
Bypass wireless
supervision
If enabled, this option will inhibit control panel
supervision of the wireless keypad.
NO Superv. WLS
Bypass tamper
If enabled, this option will inhibit wireless keypad
tamper signalling on the control panel.
Disable tamp. WLS
Domotic Out-
puts enabling
Section for the selection of the outputs for home
automation, that can be activated without a valid
code (see paragraph 6-2-1 Outputs activatable
without authentication).
Not available
Thermostat on
keypad
This key directly accesses the programming section of
the “Thermostat ON” event
Configured keypads ,
selected keypad
Events, Thermostat ON
Valid code at
keypad
This key directly accesses the programming section of
the “Valid code at keypad” event
Events, Valid Code
Temperature
adjustment
This parameter allows you to enter the effective value
of the room temperature read by an external
thermometer. This value will replace the keypad
temperature reading and thus allow you to correct
the temperature sensor on the keypad you are
working on (valid for keypads with temperature
sensors only).
The entered value must be expressed in °C decimals
(for example, type in 252 if the temperature is 25.2
°C).
Not available
Other parameters, Temp.
adjustment
Table 3-2: Parameters for single keypads