INIM Electronics Prime - 2. Change the descriptions of the partitions; 3. Program the zones (all connected to the control panel); 4. Add a third partial arming scenario (Stay mode) to the default scenarios; 5. Associate the “Ground floor” and “First floor” partitions with the readers, and scenario 3 Stay mode

INIM Electronics Prime
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming manual
Programming example 89
Click-on the
Settings
button on the menu bar, set up the connection to the control panel.
in order to have the system configuration available, perform a read operation using the
Read
button.
PROGRAMMING
PARTITIONS
2. Change the descriptions of the partitions:
Partition 1 - “Ground floor”
Partition 2 - “First floor
Via keypad
PROGRAMMING Partitions, "Partition 00x", Description
Via software
Click on the
Partitions
button on the menu on the left, the “Programming” section on the
right will show the list of available partitions.
Here, by selecting the partition to set up, it is possible to change the parameter “Description”.
PROGRAMMING
ZONES
3. Program the zones (all connected to the control panel):
Via keypad
PROGRAMMING Terminals,
select the terminal concerned
or
PROGRAMMING Zones,
select the zone associated with the terminal concerned
Via software
To program the zone, select the
Terminals
button. The “Programming” section on the right
will show the graphic representation (map) of the terminals of the entire system.
By double clicking on the terminal concerned you will enter the terminal programming phase.
PROGRAMMING
SCENARIOS
4. Add a third partial arming scenario (Stay mode) to the default scenarios (Scenario 1
Away mode” and Scenario 2 “Disarm”) of both partitions.
Via keypad
PROGRAMMING Arming scenarios, "SCENARIO 003", Partitions, "partition", Stay
Via software
Click-on the
Arming scenarios
button on the menu on the left, the “Programming” section
on the right will show the list of available scenarios.
Here, select scenario 3, set “Stay mode” for the “Ground floor” and “First floor” partitions.
PROGRAMMING
READERS
5. Associate the “Ground floor” and “First floor” partitions with the readers, and scenario 3
Stay mode (arm partially) to the default scenarios:
Via keypad
PROGRAMMING Readers, ChoosePeripheral, "READER 00x", Partitions
In this section you can enable the “Ground floor” and “First floor” partitions.
PROGRAMMING Readers, ChoosePeripheral, "READER 00x", Shortcut
In this section you can select the shortcut associated with the red and blue LEDs by first
selecting the “Arm/disarm” type then the scenario to associate with the LED.
Table 22-2: Zone parameters
Device Description Partition Zone type Option Balancing Detector type
A
Roller blind detector Ground floor Instant None Normally closed Roller blind
B
Motion detector
entrance
Ground floor Delayed Interior Normally closed Generic zone
C
Magnetic contact
entrance door
Ground floor Delayed None Normally closed Generic zone
D
Magnetic contact garage
shutter
Ground floor Instant None Normally closed Generic zone
E
Motion detector living
room
Ground floor Instant None Normally closed Generic zone
F
Magnetic contact win-
dow 1 bedroom
First floor Instant None Normally closed Generic zone
G
Magnetic contact win-
dow 2 bedroom
First floor Instant None Normally closed Generic zone
H
Motion detector bed-
room
First floor Instant None Normally closed Generic zone