90 Programming example
Centrali anti-intrusione
Via software
Click-on the
Readers
button, the “Programming” section on the right will show all the
configured readers.
Clicking-on the button accesses the section where you can select the partitions to associate
with the reader and associate the shortcut with the red and blue LEDs.
PROGRAMMING
KEYPAD
6. Associate the keypad with the “Ground floor” and “First floor” partitions.
Via keypad
PROGRAMMING Keypads, ChoosePeripheral, KEYP. 001", Partitions
In this section you can enable the “Ground floor” and “First floor” partitions.
Via software
Click-on the
Keypads
button, the “Programming” section on the right will show the configured
keypad.
Here you can associate the keypad with the partitions.
PROGRAMMING
EXPANSIONS
7. To program the devices connected to the expansion terminals:
Via keypad
PROGRAMMING Terminals,
select the terminal concerned
Press the button to configure the terminal as an output. Press
OK
to access the
programming menu.
Via software
To program the zone, select the
Terminals
button. The “Programming” section on the right
will show the graphic representation (map) of the terminals of the entire system.
Right clicking-on the expansion terminal will allow you to configure it as an output, after which
a double click will access the terminal programming phase.
PROGRAMMING
KEYS
8. Associate the keys (
[O]
and
[P]
) with the “Ground floor” and “First floor” partitions:
Via keypad
PROGRAMMING Keys, Change key, "Key 00x", Partitions
In this section you can enable the “Ground floor” and “First floor” partitions.
Via software
Click-on the
Keys
button, in the "Programming" section on the right you will be able to view
the keys and the partitions to associate with them.
9. Enroll the keys, using one of the proximity readers and/or a keypad.
Via keypad
PROGRAMMING Keys, Enroll, "Reader 00x", "Key 00x"
Hold the key in the vicinity of the reader and then move it away. The keypad you are working
on will emit a beep to confirm that the key has been enrolled.
PROGRAMMING
WIRELESS
KEYFOBS
10. Associate the shortcuts for the arm/disarm commands and control of expansion outputs
to the keyfob command buttons
[O]
Via keypad
PROGRAMMING Keys, Key parameters, "Key 00x", Shortcut
Table 22-3: Reader parameters
Device Description Partitions Red LED shortcut Blue LED shortcut
I
Reader entrance door
Ground floor
First floor
Default Default
J
Keypad
(built-in reader)
Ground floor
First floor
Default
Execute “Scenario
3” arming mode
K
Reader bedroom
Ground floor
First floor
Execute “Scenario
3” arming mode
None
Table 22-4: Expansion parameters
Device Terminal Description Type Output options Monostable time
L
1
Gate Output Monostable 30 seconds
2
Garden lights Output
Monostable
Switch
60 minutes