106 Compliance with rules in force
Anti-intrusion control panels
•• G1 power system fault (overvoltage, overcurrent, short circuit)
•• G2 mains power failure fault
•• G3 battery fault
• Connect the backup battery to the battery-charge-level control system of the
certified power supply unit.
• Power the control panel by means of a continuous current output of the certified
power supply, by wiring it through cable J of the connector on the control panel
(Table 2-8: Mother board - description of parts, B) in respect of polarity (BLACK =
negative, RED = positive) and, if necessary, by extending the cable.
• Draw the POSITIVE power supply for all the system parts (control panel, peripherals,
detectors, etc.) exclusively from the certified power supply unit.
• Prepare 3 input terminals for the fault signal connections (G1, G2, G3, described
above) and program the following parameters for each of the 3 terminals:
•• “Description”: assign an explanatory description to the signal
•• “Fault zone”: enable this option