74 Options and programming methods
Anti-intrusion control panels
Telephone notifications (calls) are queued and sent out in chronological order. However,
some events may need to be notified immediately (for example, use of a code under
duress), therefore, such events can be given priority by selecting the “Priority” option.
Event notification via e-mail requires the use of a SmartLAN/G board (refer to
paragraph 3-10-3 SmartLAN).
Event notification via predefined SMS messages requires the use of a Nexus (refer to
paragraph 7-29-3 Text for SMS messages).
Note
If a list of telephone calls is programmed for the notification of an event as well as SMS
messages, the SMS messages will be sent before the telephone calls.
The following table shows the events the control panel recognizes, the number of
events for each type, the trigger and restoral method of each event and the event
category (Pulse).
Table 7-6:
Event type
Name Occurs when... Restores when ... Number of events
Pulse
events
Control panel
models
Zone alarm
A zone generates an alarm A zone restores
One event for each
zone
no all
Terminal tamper
A terminal detects tamper (short-cir-
cuit or wire cutting)
A terminal restores
One event for each
terminal
no all
Partition alarm
A 24h zone which belongs to the parti-
tion generates an alarm, or a zone
which belongs to the partition generates
an alarm during Away mode.
All the zones belonging to the par-
tition restore (reset).
One event for each
partition
no all
StayPartit.alarm
A zone which belongs to a partition
armed in Stay or Instant mode, gener-
ates an alarm.
All the zones belonging to the par-
tition restore (reset).
One event for each
partition
no all
Partition tamper
A zone which belongs to the partition
detects tamper (short-circuit or wire
cutting).
All the zones belonging to the par-
tition restore (reset).
One event for each
partition
no all
Zone bypass
A zone is inhibited A zone is enabled (switched On)
One event for each
zone
no all
Real-time zone
The electrical status of a zone switches
from standby to alarm
The electrical status of a zone
switches from alarm to standby
One event for each
zone
no
all
The event is independent of the zone type and the armed/disarmed status of
the partitions.
all
Partit.not ready
A zone which belongs to the partition is
not in standby status.
All the zones belonging to the par-
tition are in standby status.
One event for each
partition
no all
Away arm request
A request is made to arm the interior
and perimeter zones of the partition
A request is made to disarm the
partition
One event for each
partition
Yes all
Overtime request
A request is made to arm the partition
in Stay mode (perimeter zones only) or
in Instant mode
A request is made to disarm the
partition
One event for each
partition
Yes all
Partit.awayArmed
The partition interior and perimeter
zones have been armed effectively
The partition will be disarmed
One event for each
partition
no all
Partit.StayArmed
armed
The partition has been armed effec-
tively in Stay or Instant mode
The partition will be disarmed
One event for each
partition
no all
Disarm partition
The partition will be disarmed The partition will be armed
One event for each
partition
no all
Partition reset
A request is made to reset the partition
One event for each
partition
Yes all
Exit time
The partition exit time starts running The partition exit time expires
One event for each
partition
no all
Entry time
The partition entry time is running The partition entry time expires
One event for each
partition
no all
Pre-arm time
The partition Pre-arm time is running The partition Pre-arm time expires
One event for each
partition
no all
Overtime request
A request for overtime relating to the
partition is made
One event for each
partition
Yes all
Chime
A chime zone belonging to the partition
is violated
One event for each
partition
Yes all
Forced arming
At the time of an arming command,
relating to one or more partitions, there
are open zones on the partition/parti-
tions involved, or there are other condi-
tions present which lower system
security, nonetheless, the user arms the
system.
One event for each
partition
Yes all