Installation and programming manual
Options and programming methods 75
Failed to arm
The “OpenZonesArmLock” option is
enabled at the time of a partition arm-
ing command and there is at least one
open zone on the partition/s involved.
or
when one or more of the conditions
described in “LossTamp.ongoing” is
present (refer to “FaultForNotReady”,
paragraph 7-27 Other parameters).
One event for each
partition
Yes all
Valid code
A user-code PIN entered at a keypad is
recognized as valid
One event for each
code
Yes all
Valid key
A key used at a reader is recognized as
valid on the reader
One event for each
key
Yes all
Valid Code AtKeyp.
A user-code PIN entered at a keypad is
recognized as valid on the keypad
One event for each
keypad
Yes all
ValidKeyAtReader
A key used at a reader is recognized as
valid on the reader
One event for each
reader
Yes all
Partition code
A user-code PIN entered at a keypad is
recognized as valid on the partition
One event for each
partition
Yes all
Partition key
A key used at a reader is recognized as
valid on the partition
One event for each
partition
Yes all
Failed call
All attempts to call a specific telephone
number have failed
One call to the phone number has
been successful
One event for each
contact telephone
number
no all
Timer activated
The timer is enabled (On) The timer is disabled (Off)
One event for each
timer
no all
Thermostat ON
The activation conditions set for the
keypad thermostat occur.
The deactivation conditions set for
the keypad thermostat occur.
One event for each
keypad
no all
Scenario ON
The status of all the partitions corre-
sponds exactly to the pre-set scenario.
The status of all least one of the
partitions does not correspond to
the pre-set scenario.
One event for each
scenario
no all
ProgrammableEvt
See paragraph 7-11-3 Programmable events no all
Emergency key
One of the emergency-key duos is
pressed
One event for each
emergency-key duo
Yes all
Panic Ev.
The “Panic” shortcut has been acti-
vated.
15 Yes all
Periodic event
The Periodic Event occurs 4 Yes all
Panel opened
The control-panel enclosure is removed
The front of the control-panel is
replaced
1noall
Dislodged panel
The control-panel enclosure is detached
from the wall
The control-panel enclosure is
reattached to the wall
1noall
Zone fuse fault
The zone protection fuse on the control
panel is not operational (blown)
The zone protection fuse on the
control panel restores
1noall
IBUS fuse fault
The I-BUS protection fuse is not opera-
tional (blown)
The I-BUS protection fuse restores 1 no all
Low battery
The backup battery is low
(voltage below 10.4V)
The backup battery is charged
(voltage above 11.4V)
1noall
Mains failure
The primary power supply 230V~ fails
The primary power supply 230V~
is restored
1noall
Expansion tamper
An expansion board signals tamper con-
ditions
Tamper conditions clear on all the
system expansion boards
1noall
Keypad tamper
A keypad signals tamper conditions
Tamper conditions clear on all the
system keypads
1noall
Reader tamper
A reader signals tamper conditions
Tamper conditions clear on all the
system readers
1noall
Sound.flash.Tamp
A sounderflasher connected to the BUS
signals tamper
All the sounderflashers connected
to the BUS reset
1noall
Nexus tamper
The GSM dialer Nexus signals tamper
Tamper conditions clear on the
Nexus
1noall
Tamp. LIVPWR100
For future use
VideoSens.Tamper
For future use
Expansion loss
An expansion board cannot be found on
the BUS
All expansion boards can be found
on the BUS
1noall
Keypad loss
A keypad cannot be found on the BUS
All keypads can be found on the
BUS
1noall
Reader loss
A reader cannot be found on the BUS
All readers can be found on the
BUS
1noall
Table 7-6:
Event type
Name Occurs when... Restores when ... Number of events