Installation and programming manual
Options and programming methods 77
Each event can be associated with 3 voice messages, selected from the message list
(refer to Appendix D, Voice messages).
• Message type
• Message A
• Message B
This feature allows you to create messages which will be played during event-related
voice calls to contact numbers, both at the start and end of the event.
The choice of messages and the number of times they are played depends on the
“AutomaticDialer” settings.
Via Keypad
1. Accessing the “Events” section
Type-in Code
(Installer PIN)
, PROGRAMMING Events .
2. Use keys and to select the event type (if you are dealing with a group
of events, repeat the required operation) and , then press .
3. Select:
• Activation, to programme the actions to be carried out when the event occurs.
• Restoral, to programme the actions to be carried out when the event ends.
4. Successively, the parameters to programme are:
TelephoneNumbers
Programme the call recipient numbers.
Message type
Message A
Message B
Select the number of the message (see Table 7-7: Event-related messages and
Appendix D, Voice messages):
1. Use keys and to select the field you wish to change, then use the number
keys ( , etc.) to edit the number.
or
Use keys and to increase or decrease the number.
Undervoltage BUS
A voltage below 9.8V has been detected
on I-BUS terminal “+” on the LIVP-
WR100 board.
The normal voltage on the termi-
nal has been restored.
1no
SmartLiving
G3
Short circuit “x”
A short-circuit has been detected on
terminal “
+AUX
” corresponding to
number “x” on the LIVPWR100 board.
The short-circuit is no longer pres-
ent.
1no
SmartLiving
G3
Short circuit BUS
A short-circuit has been detected on I-
BUS terminal “+” on the LIVPWR100
board.
The short-circuit is no longer pres-
ent.
1no
SmartLiving
G3
Overload “x”
A load of over 1.5A has been detected
on terminal “
+AUX
” corresponding to
number “x” on the LIVPWR100 board.
The terminal restores to normal. 1 no
SmartLiving
G3
Overload BUS
A load of over 3.5A has been detected
on I-BUS terminal “+” on the LIVP-
WR100 board.
The terminal restores to normal. 1 no
SmartLiving
G3
NoCommunPwSuppl
y
Communication between the power
supply unit and the control panel has
broken down.
Communication between the
power supply unit and the control
panel restores.
1no
SmartLiving
G3
Tel. on number 1
A call has been sent to phone number 1
The call has ended (even in the
event of negative outcome)
1noall
Tel.on number 15
A call has been sent to phone number
15
The call has ended (even in the
event of negative outcome)
1noall
Sync.data IP2RX
The IP2RX synchronization process has
been carried out from a keypad (refer
to the User Manual, “Activations”)
1Yesall
IP conn. lost
The IP connectivity test is enabled and
the test result in negative (failed).
A connection attempt has been
successful.
1noall
IP conn. lost
Nexus/G has detected GPRS connectiv-
ity trouble.
The GPRS connectivity is restored. 1 no all
Table 7-6:
Event type
Name Occurs when... Restores when ... Number of events
Pulse
events
Control panel
models
Events
Activation
Restoral
Zone alarm
Panel T01
Panel T02
Panel T03
PROGRAMMING
Walk test
Telephone
Events
Events
Zone alarm
Terminal tamper
Partition alarm