Appendix. Parameter Table
- 317 -
12
Parameter
No.
Parameter Name Setting Range Default Property Page
F8-17 Accumulative running time
threshold
0 to 65000 h 0 h
-
F8-18 Startup protection selection 0, 1 0
-
F8-19 Frequency detection value 1 0.00 Hz to max. frequency 50.00 Hz
1
9
5
F8-20 Frequency detection hysteresis 1 0.0% to 100.0% 5.0%
1
9
5
F8-21 Detection width of target
frequency reached
0.0% to 100.0% 0.0%
1
9
5
F8-22 Jump frequency function 0, 1 0
1
9
3
F8-25 Switchover frequency of accel
time 1 and accel time 2
0.00 Hz to max. frequency 0.00 Hz
1
9
6
F8-26 Switchover frequency of decel
time 1 and decel time 2
0.00 Hz to max. frequency 0.00 Hz
1
9
6
F8-27 Set highest priority to terminal
JOG function
0, 1 0
1
9
2
F8-28 Frequency detection value 2 0.00 Hz to max. frequency 50.00 Hz
1
9
5
F8-29 Frequency detection hysteresis 2 0.0% to 100.0% 5.0%
1
9
5
F8-30 Detection of frequency 1 0.00 Hz to max. frequency 50.00 Hz
1
9
7
F8-31 Detection width of frequency 1 0.0% to 100.0% (max.
frequency)
0.0%
1
9
7
F8-32 Detection of frequency 2 0.00 Hz to max. frequency 50.00 Hz
1
9
7
F8-33 Detection width of frequency 2 0.0% to 100.0% (max.
frequency)
0.0%
1
9
7
F8-34 Zero current detection level 0.0% to 300.0% (rated motor
current)
5.0%
1
9
7
F8-35 Zero current detection delay 0.01s to 600.00s 0.10s
1
9
7
F8-36 Output overcurrent threshold 0.0% (no detection)
0.1% to 300.0% (rated motor
current)
200.0%
1
4
6
F8-37 Output overcurrent detection
delay
0.00s to 600.00s 0.00s
1
4
6
F8-38 Detection level of current 1 0.0% to 300.0% (rated motor
current)
100.0%
1
9
8
F8-39 Detection width of current 1 0.0% to 300.0% (rated motor
current)
0.0%
1
9
8
F8-40 Detection level of current 2 0.0% to 300.0% (rated motor
current)
100.0%
1
9
8
F8-41 Detection width of current 2 0.0% to 300.0% (rated motor
current)
0.0%
1
9
8
F8-42 Timing function 0, 1 0
1
9
8
F8-43 Running time setting channel 0 to 3 0
1
9
8
F8-44 Running time 0.0 to 6500.0 min 0.0 min
1
9
8
F8-45 AI1 input voltage lower limit 0.00 V to F8-46 3.10 V
1
9
9
F8-46 AI1 input voltage upper limit F8-45 to 10.00 V 6.80 V
1
9
9
F8-47 Module temperature threshold 0°C to 100°C 75°C
1
9
9

Table of Contents