EasyManuals Logo
Home>Intel>Server Board>5000 Series

Intel 5000 Series User Manual

Intel 5000 Series
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
System Management Intel® 5000 Series Chipsets Server Board Family Datasheet
Revision 1.1
Intel order number D38960-004
100
Serial Over LAN (SOL)
ACPI state synchronization – The BMC tracks ACPI state changes (provided by BIOS).
BMC self test – The BMC performs initialization and run-time self tests and makes
results available to external entities.
4.1.1.2 Non-IPMI Features
This section lists non-IPMI feature support carried over from prior generation of servers.
PSMI 1.44-compliant power system monitoring, including support for power gauge and
power nozzle sensors. Prior generation platforms supported PSMI 1.42, which was very
similar to PSMI 1.44).
Fault resilient booting (FRB) support – FRB2 is supported via watchdog timer
functionality.
BMC firmware update using firmware transfer mode operation
BMC on-line update – BMC rolling update, which supports a redundant firmware image.
Power state retention
Chassis intrusion detection is supported on some platforms
FRU fault LED support – The BMC lights server LEDs to indicate failed components.
Basic fan control using TControl ver.1 SDRs.
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Signal testing support – The BMC provides test commands for setting or getting various
platform signal state
Beep code generation – The BMC generates diagnostic beep codes for various fault
conditions
Hot-swap backplane support – The BMC pushes power supply state to HSC
System GUID storage and retrieval
Front Panel management – The BMC controls system fault LED and chassis ID.
Supports secure lockout of certain front panel functionality. Monitors button presses. The
chassis ID can be turned on via front panel button or command.
Power unit management – Support for power unit sensor. This handles power-good
dropout condition.
NMI – Provides commands to set/get NMI source. Supports generation of NMI due to
watchdog timer, IPMI command, or front panel NMI button. Monitors system NMI signal.
ARPs – The BMC can send and respond to ARP. This is supported on Intel
®
631xESB /
632xESB I/O Controller Hub embedded NICs
DHCP – The BMC can perform DHCP. This is supported on Intel
®
631xESB / 632xESB
I/O Controller Hub embedded NICs

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel 5000 Series and is the answer not in the manual?

Intel 5000 Series Specifications

General IconGeneral
BrandIntel
Model5000 Series
CategoryServer Board
LanguageEnglish

Related product manuals