Intel® 5000 Series Chipsets Server Board Family Datasheet System BIOS
Revision 1.1
Intel order number D38960-004
51
Table 12. Runtime Error Handling, with Redundancy
Scenario POST Message SEL LED State IPMI MEM States
Updated
System Operation
Runtime:
Config = SPARE
CE < Threshold
None, because the
BIOS does not retain
the memory state
information across
reboots.
CE SEL message
identifying FBDIMM
location
DIMM fault LED:
Not lit.
System fault LED:
Not lit.
No The system continues to operate
normally.
Runtime:
Config = Spare
CE >= Threshold
None, because the
BIOS does not retain
the memory state
information across
reboots.
CE SEL Identifying
FBDIMM location
Threshold reached SEL
identifying FBDIMM
location
CE logging stopped
DIMM fault LED:
Lit in lock-stepped
mode for the failed
pair of FBDIMMs.
In single-channel
mode, lit for the
failed FBDIMM.
System fault LED:
Green / blink.
Fail status = Y
Disable status = Y
Spare status =
Spare 1 / 0
RAS Redundancy
State Redundant /
Non-redundant
The system continues to operate
normally. System transitions to non-
redudant mode. The BIOS will mask all
correctable memory errors.
Runtime:
Config = Spare
Current State: Non-
Redundant
(Post-SFO)
UE
None, because the
BIOS does not retain
the memory state
information across
reboots.
UE SEL Identifying
FBDIMM location
DIMM fault LED:
Lit if dual-channel
mode, for a pair of
FBDIMMs, else for
a single FBDIMM.
System fault LED:
Amber / on.
Fail status = Y The system will NMI.
Runtime:
Config = SPARE
Current State:
Redundant
(Pre-SFO)
UE
None, because the
BIOS does not retain
the memory state
information across
reboots.
UE SEL Identifying
FBDIMM location
DIMM fault LED:
Lit if dual-channel
mode, for a pair of
FBDIMMs.
Else lit for a single
FBDIMM.
System fault LED:
Amber / on.
Fail status = Y The system will NMI.
Runtime:
Config = MIR
Current State:
Redundant
CE >= Threshold
None, because the
BIOS does not retain
the memory state
information across
reboots.
CE SEL Identifying
FBDIMM location
CE Max SEL identifying
FBDIMM location
DIMM fault LED:
Lit for the failed
pair.
System fault LED
state: Green / blink
Fail Status = Y
Disable Status = N
Operating system continues to operate
normally. The BIOS will mask all
correctable errors.