System BIOS Intel® 5000 Series Chipsets Server Board Family Datasheet
Revision 1.1
Intel order number D38960-004
52
Scenario POST Message SEL LED State IPMI MEM States
Updated
System Operation
Runtime:
Config = MIR,
and Current State:
Redundant
UE
None, because the
BIOS does not retain
the memory state
information across
reboots.
UE SEL message
identifying FBDIMM
location
DIMM fault LED:
Lit for the failed
FBDIMM pair.
System fault LED:
Green / blink
Fail status = Y
Disabled Status = Y for
all FBDIMMs on the
failed branch / group
The system will NMI.