The following example illustrates recovery from a corrupted image:
Multiple Corrupted Images
If the flash memory includes multiple corrupted images, the RSU_STATUS only reports status for the highest priority failing
image. The following example illustrates this procedure.
The flash memory includes the following four images, in order of priority:
1. Application Image3 (highest priority)
2. Application Image2
3. Application image1
4. Application image0 (lowest priority)
Application Image3, Application Image2, and Application Image1 are corrupted.
RSU_STATUS includes the following information:
Current_Image: Application Image0
Highest priority failing image, State, Version, Error location, Error details: records information
for Application Image3 which is the highest priority failing image.
5. Remote System Update (RSU)
683673 | 2021.10.29
Intel
®
Agilex
Configuration User Guide
Send Feedback