The power management activity is ongoing during the device configuration. For more information, refer to the Intel Agilex
Power Management User Guide.
The SDM drives the CONF_DONE pin high after successfully receiving full bitstream.
The CONF_DONE pin signals an external host that bitstream transfer is successful.
Failed FPGA Configuration
A low pulse on the nSTATUS pin indicates a configuration error.
An internal device wipe occurs followed by errors requiring reconfiguration.
After a low pulse indicating an error, configuration stops. The nSTATUS pin remains high.
Following an error, the SDM drives nSTATUS low after the external host drives nCONFIG low.
The device enters Idle state after the nSTATUS pin recovers to initial pre-configuration low state.
User Mode
The SDM drives the INIT_DONE pin high after initializing internal registers and releases GPIO pins from the high
impedance state. The device enters user mode. After CONF_DONE asserts and before INIT_DONE asserts, parts of the
device start to enter user mode. The assertion of INIT_DONE indicates that the entire device entered user mode. Intel
requires you to include the Reset Release in your design. Use the nINIT_DONE output of the Reset Release Intel FPGA IP
to hold your application logic in the reset state until the entire FPGA fabric is in user mode. Failure to include this IP in
your design may result in intermittent application logic failures.
The nCONFIG pin should remain high in user mode.
You may re-configure the device by driving nCONFIG pin from low to high.
Device Clean
In the Device Clean state the design stops functioning.
Device cleaning zeros out all configuration data.
The Intel Agilex device drives CONF_DONE and INIT_DONE low.
The SDM drives the nSTATUS pin low when device cleaning completes.