Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor
Tables
Revision 1.1
Intel order number G34153-003
133
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Supply 1
Temperature
(PS1
Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2
Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Hard Disk Drive
16 - 24 Status
(HDD 16 - 24
Status)
60h
68h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive
Presence
OK
As and De
Trig
Offset
A
X
01- Drive Fault
Degraded
07 -
Rebuild/Remap in
progress
Degraded
69h
-
6Bh
Chassis-
specific
Microcontroller
16h
Discrete 0Ah
04- transition to
Off Line
Degraded
Trig
Offset
X
Processor 1
Status
(P1 Status)
70h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and De
Trig
Offset
M
X
07 - Presence
OK
Processor 2
Status
(P2 Status)
71h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and De
Trig
Offset
M
X
07 - Presence
OK
Processor 3
Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and De
Trig
Offset
M
X
07 - Presence
OK
Processor 4
Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and De
Trig
Offset
M
X
07 - Presence
OK