Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Revision 1.1
Intel order number G34153-003
132
Full Sensor
Name
(Sensor name
in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib.
To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
06 Configuration
error
OK
Power Supply 2
Status
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06 Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Power Supply 1
+12V % of
Maximum
Current Output
(PS1 Curr Out
%)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X
Power Supply 2
+12V % of
Maximum
Current Output
(PS2 Curr Out
%)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and De
Analog
R, T
A
X

Table of Contents